Receiving an “Unsatisfactory” Electrical Installation Condition Report (EICR) can feel overwhelming for any UK landlord. However, understanding the exact EICR failure codes explained in your report is the key to resolving defects quickly, avoiding civil penalties up to £30,000, and keeping your tenants safe.

The 28-Day Legal Clock

Under UK electrical safety regulations, landlords have a strict statutory deadline of 28 days (or sooner if specified) to complete mandatory remedial works.

Failure to carry out required electrical repairs or produce written confirmation of compliance exposes landlords to local authority financial penalties up to £30,000 per breach under the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020.

What Does an “Unsatisfactory” EICR Outcome Actually Mean?

An Electrical Installation Condition Report (EICR) provides an in-depth assessment of the permanent wiring, consumer units, sockets, switches, and earthing arrangements within a property. The final page of the report delivers an overall assessment: either Satisfactory or Unsatisfactory.

Under BS 7671 (the 18th Edition IET Wiring Regulations), an EICR is declared Unsatisfactory if the qualified inspector observes one or more faults classified as:

  • Code C1: Danger Present (immediate risk)
  • Code C2: Potentially Dangerous (urgent remedial action required)
  • Code FI: Further Investigation required without delay

Crucially, observations classified solely as Code C3 (Improvement Recommended) do not make an EICR unsatisfactory on their own. Knowing how these classification codes operate protects you from unnecessary re-wiring expenses while highlighting genuine safety hazards that require immediate electrical remediation.

Electrician testing consumer unit wiring during an EICR inspection in a UK rental property
A registered electrician performing circuit diagnostic checks on a residential consumer unit during an EICR inspection.

Deconstructing EICR Observation Classification Codes

When an engineer inspects a rental property, every deviation from current 18th Edition wiring standards is recorded in the observation schedule. Each item receives a specific code determining its legal severity:

Classification Code Standard Definition Impact on Overall EICR Action Required by Landlord
Code C1 Danger Present: Risk of injury is present. Immediate remedial action required. Automatic Unsatisfactory Immediate make-safe or disconnection on site; urgent repair.
Code C2 Potentially Dangerous: Urgent remedial action required to prevent hazard. Automatic Unsatisfactory Remedial repair required within 28 days (or shorter if specified).
Code FI Further Investigation: Observation cannot be fully confirmed without deeper analysis. Automatic Unsatisfactory Investigation and resolution required within 28 days.
Code C3 Improvement Recommended: Non-compliance with latest standards but safe. Remains Satisfactory Advisory only. Recommended during future maintenance or renovations.

Code C1: Danger Present — Immediate Action Required

EICR C1 code danger present is the most critical defect classification in UK electrical testing. It signifies that someone using the electrical installation is at immediate risk of electric shock or electrical fire.

When an NICEIC or NAPIT-accredited inspector identifies a C1 condition during an inspection, they have a professional duty to inform the landlord or tenant immediately and take prompt make-safe action — such as isolating the dangerous circuit or placing a temporary barrier over exposed live parts.

Common Examples of C1 Observations

  • • Exposed live conductors: Smashed socket faceplates, exposed wiring cores accessible to touch, or open consumer unit knockouts revealing live busbars.
  • • Live conductive parts: Metal light fittings or exposed pipework that have become energised due to a breakdown in insulation.
  • • Reverse polarity: Live and neutral connections reversed at the main incoming supply or across socket outlets.
  • • Severe thermal damage: Charred or actively melting consumer unit components presenting an imminent fire ignition risk.

Code C2: Potentially Dangerous — Urgent Remedial Action Needed

An EICR C2 potentially dangerous code indicates that while a defect does not pose an immediate hazard under normal resting conditions, the failure of another basic safety component (such as an earthing conductor or insulation layer) would immediately result in severe danger.

C2 codes are the single most common reason residential rental properties fail their 5-year EICRs across Greater London. They must be rectified within 28 days to restore statutory compliance.

Typical Code C2 Defects in UK Rental Homes



  • Absence of Earth Continuity:

    Metal light fittings, cooker circuits, or socket outlets that lack a continuous protective earth conductor to the main earthing terminal.



  • Lack of 30mA RCD Protection in Special Locations:

    Sockets located outdoors or circuits supplying bathroom electrical equipment (e.g. electric showers) without 30mA Residual Current Device (RCD) shock protection.



  • Inadequate Cable Sizing or Over-Fused Circuits:

    A circuit protection device (fuse or MCB) rated higher than the current-carrying capacity of the connected cable, creating an overheating and fire hazard.



  • Absence of Main Protective Bonding:

    Missing or severed earth bonding conductors to incoming metallic water mains or gas service pipework.

Code C3: Improvement Recommended — Does This Fail the Certificate?

One of the most frequent misconceptions among landlords is believing that an EICR code C3 improvement recommended fails the inspection. It does not.

A C3 observation means an electrical arrangement does not comply with the latest 18th Edition wiring standards (BS 7671:2018+A2:2022), but it is not inherently dangerous. If a report contains only C3 observations and no C1, C2, or FI codes, the overall outcome remains Satisfactory.

Common C3 Observations (Advisory Only)

  • • Absence of Surge Protection Devices (SPD) at the consumer unit.
  • • Absence of Arc Fault Detection Devices (AFDD) in domestic circuits.
  • • Plastic consumer units installed in domestic premises prior to the metal enclosure requirement (provided the enclosure is undamaged and secure).
  • • Wiring color differences (e.g. older red/black cables mixed with brown/blue harmonised wiring without warning labels).

Code FI: Further Investigation Required Without Delay

The Code FI is assigned when the inspector encounters an apparent defect or abnormal circuit reading that cannot be fully diagnosed within the agreed scope of a standard periodic inspection.

Because unconfirmed safety issues cannot be ruled safe, UK regulations mandate that an FI code results in an Unsatisfactory EICR until targeted electrical fault finding is completed.

Examples include unidentified circuits feeding hidden extensions, unlabelled cables terminated in inaccessible ceiling voids, or circuits displaying erratic insulation resistance test values requiring tracing.

The 28-Day Legal Clock: Landlord Responsibilities After an Unsatisfactory Report

Under Regulation 3(4) of the Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020, landlords must follow a strict, legally mandated workflow once an unsatisfactory EICR is issued:

1

Commission Qualified Remedial Works

Instruct a qualified and registered electrician (such as NICEIC, NAPIT, or ELECSA registered) to undertake the remedial repairs or further investigation specified in the report within 28 calendar days, or sooner if the report specifies a shorter period.

2

Obtain Written Confirmation & Certification

Ensure the electrician provides either a Minor Electrical Installation Works Certificate (MEIWC), an Electrical Installation Certificate (EIC) (e.g. following a consumer unit replacement), or written Confirmation of Remedial Works detailing that all C1, C2, and FI items have been rectified.

3

Serve Written Proof to Existing Tenants

Supply a copy of the written confirmation of remedial works alongside the original unsatisfactory EICR to all tenants residing in the property within 28 days of completion.

4

Submit Proof to Local Housing Authority

If the local council requested the report or issued an enforcement notice, send the written confirmation and original EICR to the council’s private rented sector housing team within 28 days of work being completed.

Do You Need a Brand New EICR After Remedial Works?

One of the costliest traps landlords face is paying for a complete, full-scope re-inspection after simple repairs. You do not need an entire new EICR from scratch unless the original installation was so severely compromised that widespread rewiring occurred.

Under statutory guidance from the Ministry of Housing, Communities & Local Government (MHCLG), legal compliance is satisfied by pairing:

  1. The original Unsatisfactory EICR detailing the initial inspection findings; plus
  2. The Minor Electrical Installation Works Certificate (MEIWC) or written Confirmation of Remedial Works signed by a registered electrician confirming each C1, C2, and FI code has been successfully repaired and re-tested.

Together, these two documents form a legally watertight compliance bundle that satisfies local authority licensing teams, mortgage lenders, and insurer underwriting requirements for the remainder of the 5-year inspection cycle.

Related Services

Complete Landlord Electrical & Compliance Services

Residential EICR

NICEIC-certified 5-year electrical safety checks with rapid digital turnaround across London.

Learn More →

Consumer Unit Upgrades

18th Edition metal fuse board replacements with dual RCD & surge protection.

Learn More →

Electrical Fault Finding

Expert diagnosis for Code FI investigation and intermittent circuit tripping.

Learn More →

Frequently Asked Questions

What is the difference between a C1 and a C2 EICR code?

A Code C1 indicates danger is actively present right now (such as live exposed wires that can be touched), posing an immediate threat to life. A Code C2 indicates a potentially dangerous situation where an existing fault would become dangerous if another component fails (such as missing earthing on metallic light fittings or sockets lacking RCD protection). Both codes trigger an automatic Unsatisfactory outcome.

Does a Code C3 fail an EICR certificate?

No. An observation coded as C3 (Improvement Recommended) does not fail an EICR. If a report contains only C3 codes and zero C1, C2, or FI codes, the overall report outcome remains Satisfactory and landlords are not legally required to undertake the recommended upgrades immediately.

Can I do the electrical remedial work myself as a landlord?

No, unless you are personally a qualified, competent electrician registered with a recognised government-approved competent person scheme (such as NICEIC or NAPIT). The 2020 Private Rented Sector regulations require remedial work and written confirmation to be completed by a qualified person with appropriate test instruments and professional indemnity insurance.

What happens if I miss the 28-day remediation deadline?

If a landlord fails to complete mandatory remedial works within 28 days, local housing authorities have statutory powers to serve a Remedial Notice. If the landlord still fails to comply, the local council can arrange for emergency remedial works to be carried out on the landlord’s behalf, recover all costs, and issue civil financial penalties of up to £30,000 per breach.

How much does it cost to fix EICR failure codes?

Remediation costs depend entirely on the specific defects identified. Minor repairs like replacing a cracked socket faceplate or restoring earth bonding are inexpensive, whereas resolving widespread circuit issues or replacing an outdated consumer unit requires dedicated quotation. For transparent repair estimates, visit our Electrical Services page.

Fast Remedial Certification

Received an Unsatisfactory EICR? We Can Fix It Fast.

Our NICEIC-certified electricians provide rapid fault diagnosis, C1 & C2 remedial repairs, and statutory minor works certification across London and the UK within 24–48 hours.

Or WhatsApp us: +44 20 8638 7006  |  info@landlordcompliancecertificate.co.uk